Innovation management

M.S. Talary, M. Mrochen. Developing ophthalmic devices in a changing EU regulatory environment. Cataract & Refractive Surgery Today Europe, 2015; February, pp. 50–53

M. S. Talary, P. Yijun Huang. Bringing an ophthalmic device to market. Is it now easier in the United States? Cataract & Refractive Surgery Today Europe, 2015; February, pp. 46–49.

P. Zakharov, M. Talary, D. Boss, M. Mrochen. Translational research: Innovate horizontally. Ophthalmologist. 2014; (1114):44-48.

Corneal laser surgery

Smadja D, Santhiago MR, Mello GR, Touboul D, Mrochen M, Krueger RR. Corneal higher order aberrations after myopic wavefront-optimized ablation. J Refract Surg. 2013;29(1):42-8. doi:10.3928/1081597X-20121210-03.

Tan J, Simon D, Mrochen M, Por YM. Clinical results of topography-based customized ablations for myopia and myopic astigmatism. J Refract Surg. 2012;28(11 Suppl):S829-36.

Wernli J, Schumacher S, Wuellner C, Donitzky C, Mrochen M. Initial surface temperature of PMMA plates used for daily laser calibration affects the predictability of corneal refractive surgery. J Refract Surg. 2012;28(9):639-44. doi:10.3928/1081597X-20120823-02.

Schumacher S, Seiler T, Cummings A, Maus M, Mrochen M. Optical ray tracing-guided laser in situ keratomileusis for moderate to high myopic astigmatism. J Cataract Refract Surg. 2012;38(1):28-34. doi:10.1016/j.jcrs.2011.06.032.

Dorronsoro C, Schumacher S, Pérez-Merino P, Siegel J, Mrochen M, Marcos S. Effect of air-flow on the evaluation of refractive surgery ablation patterns. Opt Express. 2011;19(5):4653-4666. doi:10.1364/OE.19.004653.

Mrochen M, Wüllner C, Krause J, Klafke M, Donitzky C, Seiler T. Technical aspects of the WaveLight FS200 femtosecond laser. J Refract Surg. 2010;26(10):S833-S840. doi:10.3928/1081597X-20100921-12.

Mrochen M, Wuellner C, Rose K, Donitzky C. Experimental setup to determine the pulse energies and radiant exposures for excimer lasers with repetition rates ranging from 100 to 1050 Hz. J Cataract Refract Surg. 2009;35(10):1806-14. doi:10.1016/j.jcrs.2009.05.021.

Padmanabhan P, Mrochen M, Viswanathan D, Basuthkar S. Wavefront aberrations in eyes with decentered ablations. J Cataract Refract Surg. 2009;35(4):695-702. doi:10.1016/j.jcrs.2008.12.022.

Mrochen M, Schelling U, Wuellner C, Donitzky C. Influence of spatial and temporal spot distribution on the ocular surface quality and maximum ablation depth after photoablation with a 1050 Hz excimer laser system. J Cataract Refract Surg. 2009;35(2):363-373. doi:10.1016/j.jcrs.2008.10.053.

Mrochen M, Schelling U, Wuellner C, Donitzky C. Effect of time sequences in scanning algorithms on the surface temperature during corneal laser surgery with high-repetition-rate excimer laser. J Cataract Refract Surg. 2009;35(4):738-46. doi:10.1016/j.jcrs.2008.12.034.

Mrochen M, Bueeler M, Donitzky C, Seiler T. Optical ray tracing for the calculation of optimized corneal ablation profiles in refractive treatment planning. J Refract Surg. 2008;24(4):S446-51.

Padmanabhan P, Mrochen M, Basuthkar S, Viswanathan D, Joseph R. Wavefront-guided versus wavefront-optimized laser in situ keratomileusis: contralateral comparative study. J Cataract Refract Surg. 2008;34(3):389-97. doi:10.1016/j.jcrs.2007.10.028.

Seiler T, Koller T, Mrochen M. Q-factor customized ablations - Reply. J Cataract Refract Surg. 2006;32(12):1982-1983. doi:10.1016/j.jcrs.2006.08.041.

Koller T, Iseli HP, Hafezi F, Mrochen M, Seiler T. Q-factor customized ablation profile for the correction of myopic astigmatism. J Cataract Refract Surg. 2006;32(4):584-9. doi:10.1016/j.jcrs.2006.01.049.

Hafezi F, Jankov M, Mrochen M, Wüllner C, Seiler T. Customized ablation algorithm for the treatment of steep central islands after refractive laser surgery. Journal of cataract and refractive surgery 32, 717-21 (2006).

Hafezi F, Jankov M, Mrochen M, Wüllner C, Seiler T. Customized ablation algorithm for the treatment of steep central islands after refractive laser surgery. Journal of cataract and refractive surgery 32, 717-21 (2006).

Mrochen M, Donges A, Korn G. [Femtosecond laser for refractive corneal surgery: foundations, mode of action and clinical applications]. Der Ophthalmol Zeitschrift der Deutsch Ophthalmol Gesellschaft. 2006;103(12):1005-1013. doi:10.1007/s00347-006-1450-4.

Mrochen M, Hafezi F, Iseli HP, Löffler J, Seiler T. [Nomograms for the improvement of refractive outcomes]. Ophthalmologe. 2006;103(4):331-8. doi:10.1007/s00347-005-1290-7.

Mrochen M, Hafezi F, Jankov M, Seiler T. Ablation profiles in corneal laser surgery. OPHTHALMOLOGE. 2006;103(3):175+. doi:10.1007/s00347-006-1316-9.

Hafezi F, Mrochen M, Seiler T. Two-step procedure to enlarge small optical zones after photorefractive keratectomy for high myopia. J Cataract Refract Surg. 2005;31(12):2254-6. doi:10.1016/j.jcrs.2005.04.026.

Mrochen M, Bueeler M, Iseli HP, Hafezi F, Seiler T. Transferring wavefront measurements into corneal ablations: an overview of related topics. J Refract Surg. 2004;20(5):S550-4.

Mrochen M, Donitzky C, Wüllner C, Löffler J. Wavefront-optimized ablation profiles: theoretical background. J Cataract Refract Surg. 2004;30(4):775-85. doi:10.1016/j.jcrs.2004.01.026.

Jankov M, Mrochen M, Seiler T. Laser intrastromal keratoplasty--case report. Journal of refractive surgery (Thorofare, N.J. : 1995) 20, 79-84 (2004).

Iseli HP, Mrochen M, Hafezi F, Seller T. Clinical photoablation with a 500-Hz scanning spot excimer laser.; 2004:831-834.

Hafezi F, Mrochen M, Fankhauser F, Seiler T. Anterior lamellar keratoplasty with a microkeratome: a method for managing complications after refractive surgery. J Refract Surg. 2003;19(1):52-7.

Mrochen M, Jankov M, Bueeler M, Seiler T. Correlation between corneal and total wavefront aberrations in myopic eyes. J Refract Surg. 2003;19(2):104-12.

Mrochen M, Semchishen V. From scattering to wavefronts--what’s in between? J Refract Surg. 2003;19(5):S597-S601.

Jankov M, Mrochen MC, Bueeler M, Seiler T. Experimental results of preparing laser-shaped stromal implants for laser-assisted intrastromal keratophakia in extremely complicated laser in situ keratomileusis cases. J Refract Surg. 2002;18(5):S639-43

Mrochen M. Revealing company secrets--please tell the truth and nothing but the truth! J Refract Surg. 2002;18(5):S644-51.

Mrochen M, Krueger RR, Bueeler M, Seiler T. Aberration-sensing and wavefront-guided laser in situ keratomileusis: management of decentered ablation. J Refract Surg. 2002;18(4):418-29.

Genth U, Mrochen M, Wälti R, Salaheldine MM, Seiler T. Optical low coherence reflectometry for noncontact measurements of flap thickness during laser in situ keratomileusis. Ophthalmology. 2002;109(5):973-8.

Mrochen M, Kaemmerer M, Seiler T. Clinical results of wavefront-guided laser in situ keratomileusis 3 months after surgery. J Cataract Refract Surg. 2001;27(2):201-7.

Mrochen M, Kaemmerer M, Mierdel P, Seiler T. Increased higher-order optical aberrations after laser refractive surgery: a problem of subclinical decentration. J Cataract Refract Surg. 2001;27(3):362-9.

Krueger RR, Seiler T, Gruchman T, Mrochen M, Berlin MS. Stress wave amplitudes during laser surgery of the cornea. Ophthalmology. 2001;108(6):1070-4.

Mrochen M, Eldine MS, Kaemmerer M, Seiler T, Hütz W. Improvement in photorefractive corneal laser surgery results using an active eye-tracking system. J Cataract Refract Surg. 2001;27(7):1000-6.

Mrochen M, Seiler T. [Fundamentals of wavefront-guided refractive corneal surgery]. Ophthalmologe. 2001;98(8):703-14.

Mrochen MC, Bueeler M, Seiler T. Wavefront-guided treatments for the management of decentered ablations. Invest Ophthalmol Vis Sci. 2001;42(4, S).

Mrochen M, Seiler T. Influence of corneal curvature on calculation of ablation patterns used in photorefractive laser surgery. J Refract Surg. 2001;17(5):S584-7.

Seiler T, Mrochen M, Kaemmerer M. Operative correction of ocular aberrations to improve visual acuity. J Refract Surg. 2000;16(5):S619-22.

Mrochen M, Semshichen V, Funk RH, Seiler T. Limitations of erbium:YAG laser photorefractive keratectomy. J Refract Surg. 2000;16(1):51-9.

Mrochen M, Kaemmerer M, Seiler T. Wavefront-guided laser in situ keratomileusis: early results in three eyes. J Refract Surg. 2000;16(2):116-21.

Mrochen MC, Kaemmerer M, Riedel P, Seiler T. Why do we have to consider the corneal curvature for the calculation of cutomized ablation profiles? Invest Ophthalmol Vis Sci. 2000;41(4, S).

Kaemmerer M, Mrochen M, Mierdel P, Seiler T. High order aberrations induced by photorefractive keratectomy (PRK) and LASIK. Invest Ophthalmol Vis Sci. 1999;40(4).

Mrochen M, Kaemmerer M, Seiler T. Why do we induce high order aberrations by photorefractive keratectomy (PRK) and LASIK? Invest Ophthalmol Vis Sci. 1999;40(4).

Mrochen M, Meinhard FP, Semshichen V, Funk RWHW, Seiler T. Photorefractive keratectomy with the erbium: YAG laser. OPHTHALMOLOGE. 1999;96(6):387-391. doi:10.1007/s003470050423.

Schmidt-Petersen H, Mrochen M, Genth U, Seiler T, Funk R. Er:YAG laser photorefractive surgery - Fundamental mode photoablation versus scanning spot. Invest Ophthalmol Vis Sci. 1997;38(4, 1):422.

Mrochen M, Seiler T. Midinfrared photorefractive surgery: technical standards and clinical aspects. Int Ophthalmol Clin. 1996;36(4):73-7.

Mrochen M, Vogler K, Glaeske N. Experiments on Q-switched solid state lasers in the 2 mum-3 mum spectral region. Laser und Optoelektronik. 1996;28(1):42-51.

Eye tracking

Bueeler M, Mrochen M. Simulation of eye-tracker latency, spot size, and ablation pulse depth on the correction of higher order wavefront aberrations with scanning spot laser systems. J Refract Surg. 2005;21(1):28-36.

Bueeler M, Mrochen M. Limitations of pupil tracking in refractive surgery: systematic error in determination of corneal locations. J Refract Surg. 2004;20(4):371-378.

Bueeler M, Mrochen M, Seiler T. Maximum permissible torsional misalignment in aberration-sensing and wavefront-guided corneal ablation. J Cataract Refract Surg. 2004;30(1):17-25. doi:10.1016/S0886-3350(03)00645-X.

Bueeler M, Mrochen M, Seiler T. Maximum permissible lateral decentration in aberration-sensing and wavefront-guided corneal ablation. J Cataract Refract Surg. 2003;29(2):257-63.

Physiological optics

Mrochen M, Büeler M. [Aspheric optics: physical fundamentals]. Ophthalmologe. 2008;105(3):224-33. doi:10.1007/s00347-008-1717-z.

Jankov MR, Iseli HP, Bueeler M, Schor P, Seiler T, Mrochen M. The effect of phenylephrine and cyclopentolate on objective wavefront measurements. J Refract Surg. 2006;22(5):472-81.

Iseli HP, Jankov M, Bueeler M, Wimmersberger Y, Seiler T, Mrochen M. Corneal and total wavefront aberrations in phakic and pseudophakic eyes after implantation of monofocal foldable intraocular lenses. J Cataract Refract Surg. 2006;32(5):762-71. doi:10.1016/j.jcrs.2005.10.032.

Iseli HP, Bueeler M, Hafezi F, Seiler T, Mrochen M. Dependence of wave front refraction on pupil size due to the presence of higher order aberrations. Eur J Ophthalmol. 2005;15(6):680-7.

Bueeler M, Iseli HP, Jankov M, Mrochen M. Treatment-induced shifts of ocular reference axes used for measurement centration. J Cataract Refract Surg. 2005;31(10):1986-94. doi:10.1016/j.jcrs.2005.03.068.

Mrochen MC, Bueeler M, Seiler T. Influence of higher order optical aberrations on refraction measurements. Invest Ophthalmol Vis Sci. 2002;43(1).

Seminogov VN, Semchishen VA, Panchenko VYY, Seiler T, Mrochen M. Scattering of light beams propagating through a dielectric surface with a large-scale roughness: II. Gaussian and non-Gaussian homogenization of scattered beams. LASER Phys. 2002;12(11):1333-1348.

Krueger RR, Mrochen M, Kaemmerer M, Seiler T. Understanding refraction and accommodation through “retinal imaging” aberrometry: a case report. Ophthalmology. 2001;108(4):674-8.

Mierdel P, Kaemmerer M, Mrochen M, Krinke HE, Seiler T. Ocular optical aberrometer for clinical use. J Biomed Opt. 2001;6(2):200-4. doi:10.1117/1.1344589.

Bueeler M, Mrochen M, Seiler T. On the meaning of tilt in wavefront sensing of the eye. Invest Ophthalmol Vis Sci. 2001;42(4, S).

Kaemmerer M, Mrochen M, Mierdel P, Krinke HE, Seiler T. Clinical experience with the Tscherning aberrometer. J Refract Surg. 2000;16(5):S584-7.

Fankhauser F, Kaemmerer M, Mrochen M, Seiler T. The effect of accomodation, mydriasis and cycloplegia on aberrometry. Invest Ophthalmol Vis Sci. 2000;41(4, S).

Kaemmerer M, Mierdel P, Mrochen M, Seiler T. Accuracy and reproducibility of wavefront measurements with the aberrometer. Invest Ophthalmol Vis Sci. 2000;41(4, S).

Mrochen M, Kaemmerer M, Mierdel P, Krinke HE, Seiler T. Principles of Tscherning aberrometry. J Refract Surg. 2000;16(5):S570-1.

Genth U, Huebscher HJ, Mrochen M, Seiler T. How does adaptation shift the center of the pupil? Invest Ophthalmol Vis Sci. 1999;40(4).

Vitreous and retinal surgery

Mrochen M, Riedel P, Donitzky C, Seiler T. Cavitation bubble formation during Erbium:YAG laser vitrectomy. Der Ophthalmol Zeitschrift der Dtsch Ophthalmol Gesellschaft. 2001;98(2):163-7.

Mrochen M, Riedel P, Donitzky C, Seiler T. Erbium: yttrium-aluminum-garnet laser induced vapor bubbles as a function of the quartz fiber tip geometry. J Biomed Opt. 2001;6(3):344-50. doi:10.1117/1.1381052.

Mrochen M, Riedel P, Kempe A, Seiler T. [Erbium:YAG laser vitrectomy: temperature measurements in different replacement materials]. Ophthalmologe. 2000;97(3):181-5.

Petersen H, Mrochen M, Seiler T. Comparison of erbium:yttrium-aluminum-garnet-laser vitrectomy and mechanical vitrectomy: a clinical study. Ophthalmology. 2000;107(7):1389-92.

Riedel P, Mrochen M, Donitzky C, Seiler T. [Motion artifacts in the vitreous body during vitrectomy]. Der Ophthalmol Zeitschrift der Dtsch Ophthalmol Gesellschaft. 2000;97(9):615-8.

Petersen H, Mrochen M, Riedel P, Seiler T. Optimized microsurgery probe for Erbium : Yag laser vitrectomy. Invest Ophthalmol Vis Sci. 1999;40(4).

Mrochen M, Petersen H, Wüllner C, Seiler T, Wullner C. Results on experimental Erbium : YAG laser vitrectomy. Klin Monbl Augenheilkd. 1998;212(1):50-54. doi:10.1055/s-2008-1034831.

Mrochen M, Vogler K. Miniature handpiece laser at 1 mum and 3 mum wavelength for medical application. Laser und Optoelektronik. 1996;28(1):38-41.

Corneal cross-linking

McQuaid R, Li J, Cummings A, Mrochen M, Vohnsen B. Second-harmonic reflection imaging of normal and accelerated corneal crosslinking using porcine corneas and the role of intraocular pressure. Cornea. 2014;33(2):125-30. doi:10.1097/ICO.0000000000000015.

McQuaid R, Mrochen M, Cummings A. The theory and art of corneal cross-linking. Indian J Ophthalmol. 2013;61(8):416.

Cummings AB, McQuaid R, Mrochen M. Newer protocols and future in collagen cross-linking. Indian J Ophthalmol. 2013;61(8):425-7. doi:10.4103/0301-4738.116076.

Mrochen M. Current status of accelerated corneal cross-linking. Indian J Ophthalmol. 2013;61(8):428-9. doi:10.4103/0301-4738.116075.

Wernli J, Schumacher S, Spoerl E, Mrochen M. The efficacy of corneal cross-linking shows a sudden decrease with very high intensity UV light and short treatment time. Invest Ophthalmol Vis Sci. 2013;54(2):1176-80. doi:10.1167/iovs.12-11409.

Schumacher S, Mrochen M, Spoerl E. Absorption of UV-light by riboflavin solutions with different concentration. J Refract Surg. 2012;28(2):91-2. doi:10.3928/1081597X-20120117-01.

Schumacher S, Mrochen M, Wernli J, Bueeler M, Seiler T. Optimization model for UV-riboflavin corneal cross-linking. Invest Ophthalmol Vis Sci. 2012;53(2):762-769 ST - Optimization Model for UV-Riboflavin. doi:10.1167/iovs.11-8059.

Iseli HP, Popp M, Seiler T, Spoerl E, Mrochen M. Laboratory measurement of the absorption coefficient of riboflavin for ultraviolet light (365 nm). J Refract Surg. 2011;27(3):195-201. doi:10.3928/1081597X-20100604-01.

Schumacher S, Oeftiger L, Mrochen MCW. Equivalence of Biomechanical Changes Induced by Rapid and Standard Corneal Cross-linking, Using Riboflavin and Ultraviolet Radiation. Invest Ophthalmol Vis Sci. 2011;52(12):9048-52. doi:10.1167/iovs.11-7818.

Hafezi F, Mrochen M, Iseli HP, Seiler T. Collagen crosslinking with ultraviolet-A and hypoosmolar riboflavin solution in thin corneas. J Cataract Refract Surg. 2009;35(4):621-4. doi:10.1016/j.jcrs.2008.10.060.

Krueger RR, Mrochen M. Introduction to the proceedings of the Third International Congress of Corneal Cross-Linking. J Refract Surg. 2008;24(7):S713-4.

Koller T, Mrochen M, Seiler T. Complication and failure rates after corneal crosslinking. J Cataract Refract Surg. 2009;35(8):1358-62. doi:10.1016/j.jcrs.2009.03.035.

Krueger RR, Mrochen M. Introduction to the proceedings of the fourth international congress of corneal cross linking. J Refract Surg. 2009;25(9):S792-3. doi:10.3928/1081597X-20090813-05.

Romppainen T, Bachmann LM, Kaufmann C, Kniestedt C, Mrochen M, Thiel MA. Effect of riboflavin-UVA-induced collagen crosslinking on intraocular pressure measurement. Invest Ophthalmol Vis Sci. 2007;48(12):5494-5498. doi:10.1167/iovs.06-1479.

Spoerl E, Mrochen M, Sliney D, Trokel S, Seiler T. Safety of UVA-riboflavin cross-linking of the cornea. Cornea. 2007;26(4):385-9. doi:10.1097/ICO.0b013e3180334f78.

Non-invasive monitoring / Glucose monitoring

Zakharov P, Scheffold F., B. Weber B, Laser Speckle Imaging of Cerebral Blood Flow, In: Optical Imaging of Neocortical Dynamics, Neuromethods, 2014 Vol. 85, pp 255-27

Zanon M, Sparacino G, Facchinetti A, Talary M, Mueller M, Caduff A, Cobelli C. Non-Invasive Continuous Glucose Monitoring with Multi-Sensor Systems: A Monte Carlo-Based Methodology for Assessing Calibration Robustness. Sensors 2013, 13(6), 7279-7295

Zanon M, Sparacino G, Facchinetti A, Riz M, Talary MS, Suri RE, Caduff A, Cobelli C. Non-invasive continuous glucose monitoring: improved accuracy of point and trend estimates of the Multisensor system. Med Biol Eng Comput. 2012 Oct;50(10):1047-57.

Peuser J., Belhaj-Saif A., Hamadjida A., Schmidlin E., Gindrat A.-D., Völker A. C., Zakharov P., Hoogewoud H.-M., Rouiller E.  and Scheffold F., Follow-up of cortical activity and structure after lesion with laser speckle imaging and magnetic resonance imaging in nonhuman primates, J. Biomed. Opt., 2011 Sep;16(9):096011.

Zanon M, Riz M, Sparacino G, Facchinetti A, Suri RE, Talary MS, Cobelli C. Assessment of linear regression techniques for modeling multisensor data for non-invasive continuous glucose monitoring. Conf Proc IEEE Eng Med Biol Soc. 2011 Aug;2011:2538-41.

Dewarrat F, Falco L, Mueller M, Reinhard S, Caduff A and Talary MS, Dielectric inverse problem applied to human skin measurements during glucose excursions, 2011, Journal of Physics in Medicine and Biology, 2011 Aug;32(8):1285-300.

Mueller M, Talary M, Falco L, Stahel W, Caduff A. Data processing for non-invasive continuous glucose monitoring with a multi-sensor device. J Diabetes Sci Technol. 2011 May 1;5(3): 703-713.

Caduff A, Mueller M, Megej A, Dewarrat F, Suri R, Klisic J, Donath M, Zakharov P, Schaub D, Stahel W.A, Talary M. Characteristics of a multisensor system for non invasive glucose monitoring with external validation and prospective evaluation. Biosens Bioelectron. 2011, 26(9): 3794-3800.

Caduff A, Heinemann L, Talary M, H. U. Lutz, di Benedetto G, Theander S. A four hour hyperglycaemic excursion induces rapid and slow changes in major electrolytes in blood in healthy human subjects. Acta Diabetologica. 2011 May.

Zakharov P, Dewarrat F, Caduff A, Talary MS. The effect of blood content on the optical and dielectric skin properties. Physiol Meas. 2011 Jan;32(1):131-49.

Zakharov P, Talary M, Kolm I, Caduff A. Full-field optical coherence tomography for the rapid estimation of epidermal thickness: study of patients with diabetes mellitus type 1. Physiol. Meas. 31 (2010) 193-205.

Caduff A, Talary M, Zakharov P. Cutaneous blood perfusion as a perturbing factor for non invasive glucose monitoring. Diabetes Technol Ther. 2010 Jan;12(1):1-9.

Zakharov P, Talary M, Caduff A. Wearable skin blood perfusion sensor optimized with partial differential pathlengths simulation. Phys Med Biol. 2009, 54(17): 5301-20.

Caduff A, Talary M, Mueller M, Dewarrat F, Klisic J, Donath M, Heinemann L, Stahel W.A. Non-Invasive Glucose Monitoring in Patients with Type 1 Diabetes: Repeatability in the same Subjects using a Multisensor System. Biosens Bioelectron. 2009, 24(9): 2778-2784.

Caduff A, Talary M, Feldman Yu. Comment on experimental methods and conclusions of impedance spectroscopy of solutions at physiological glucose concentrations. Biophys Chem. 2008 Feb;132(2-3):165-6.

Caduff A, Donath M, Talary M, Haug S, Huber D, Stahel W, Dewarrat F, Jonasson L, Krebs HJ, Klisic J. Multisensor Concept for non-invasive Physiological Monitoring. Instrumentation and Measurement Technology Conference Proceedings, 2007 IEEE: 1-3 May 2007:1 – 4.

Talary M, Dewarrat F, Huber D, Caduff A. In vivo Life Sign Application of Dielectric Spectroscopy and non invasive Glucose Monitoring. J non Cryst Solids. 2007, 353(47): 4515-4517.

Livshits L, Caduff A, Talary M, Feldman Yu. Dielectric Response of Biconcave Erythrocyte Membranes to D- and L- Glucose. J Phys D: Appl Phys. 2007, 40(1): 15-19.

Huber D, Talary M, Dewarrat F, Caduff A. The Compensation of Perturbing Temperature Fluctuation in Glucose Monitoring Technologies Based on Impedance Spectroscopy. Med Biol Eng Comput. 2007; Sep;45(9):863-76.

Caduff A, Dewarrat F, Talary M, G. Stalder, L. Heinemann, Feldman Yu. Non-invasive glucose monitoring in patients with diabetes: A novel system based on impedance spectroscopy. Biosens Bioelectron. 2006, 22(5): 598-604.

Talary M, F. Dewarrat, Caduff A, Puzenko A, Ryabov Y, Feldman Yu. An RCL sensor measuring dielectrically lossy materials in the MHz frequency range. 1. Comparison of Hydrogel Model Simulation and with actual hydrogel impedance measurements. IEEE Transactions on Dielectrics and Electrical Insulation 2006, 13(2): 247-256.

Forst T, Caduff A, Talary M, Weder M, Brändle M, Kann P, Flacke F, Pfützner A. Impact of Environmental Temperature on Skin Thickness and Microvascular Blood Flow in Diabetic and Non-Diabetic Subjects. Diabetes Technol Ther. 2006 Feb;8(1):94-101.

Dynamic light scattering

Zakharov P, Scheffold P., Advances in dynamic light scattering techniques. In: A.A. Kokhanovsky, ed. Light Scattering Reviews 4. Heidelberg: Springer, 2009:433–468.

Lapointe C, Zakharov P, Enderli F., Feurer T., Skipetrov S and Scheffold F, Numerical study of Anderson localization of terahertz waves in disordered waveguides, Europhysics Letters, 2014, 105(3), 34002

Skipetrov S E, Peuser J, Cerbino R, Zakharov P, Weber B, Scheffold F, Noise in laser speckle correlation and imaging techniques, Optics Express, 2010; 18, 14519-14534.

Zakharov P and Scheffold F, Monitoring spatially heterogeneous dynamics in a drying colloidal thin film, Soft Materials, 2010; 8(2), 102 - 113.

Zakharov P, Völker A.C. , Wyss M.T., Haiss F., Calcinaghi N., Zunzunegui C., Buck A. , Scheffold F., Weber B., Dynamic laser speckle imaging of cerebral blood flow, Optics Express, 2009; 17(16):13904-17.

Zimnyakov D A, Sadovoi A V, Vilenskii M A, Zakharov P V and Myllylä R, Critical behavior of phase interfaces in porous media: Analysis of scaling properties with the use of noncoherent and coherent light, Journal of Experimental and Theoretical Physics, 2009, 108(2): 311-325.

Zakharov P, Scheffold F, Advances in dynamic light scattering techniques, In: A.A. Kokhanovsky, ed. Light Scattering Reviews 4. Heidelberg: Springer, 2009: 433–468.

Zakharov P, Völker A C, Buck A, Weber B, and Scheffold F, Quantitative modeling of laser speckle imaging, Optics Letters, 2006, Vol. 31, Issue 23, pp. 3465-3467.

Balog S, Zakharov P, Scheffold F and Skipetrov S E, Photocount statistics in mesoscopic optics, Phys. Rev. Lett., 2006, 97, 103901.

Zakharov P., Cardinaux F. and Scheffold F., “Multi-speckle diffusing wave spectroscopy with a single mode detection scheme”, Phys. Rev. E, 73, 011413 (2006).

Zakharov P, Bhat S, Schurtenberger P, Scheffold F, Multiple scattering suppression in dynamic light scattering based on a digital camera detection scheme, Applied Optics, 45 (8), 1756-1764 (2006).

Völker A C, Zakharov P, Weber B, Buck F and Scheffold F, Laser speckle imaging with an active noise reduction scheme, Optics Express,13(24), pp. 9782 – 9787 (2005).

Zakharov P, Zimnyakov D A, “The Wavelet Analysis of Fluctuations of a Laser Radiation Scattered from Interphase Boundaries in Porous Media”, Technical Physics Letters, Vol. 28, No. 12, pp. 1015-1017 (2002).

Zimnyakov D A, Sviridov A P, Omel’chenko A I, Trifonov V A, Agafonov D N, Zakharov P V, Kuznetsova L V, Speckle Diagnostics of relaxation proceses in non-stationary scattering systems”, Applied Nonlinear Dynamics, Vol.10, N3, pp. 188-204 (2002).

Zimnyakov D A, Zakharov P V, Trifonov V A, and Chanilov O I, Dynamic Light Scattering Study of the Interface Evolution in Porous Media, JETP Letters, Vol. 74 (4), pp. 216-221 (2001).

Zimnyakov D A, Sinichkin Yu P, Zakharov P V and Agafonov D N, Residual polarization of non-coherently backscattered linearly polarized light: the influence of the anisotropy parameter of the scattering medium, Waves in Random Media, Vol. 11, p. 395. (2001).

Dielectric spectroscopy

Ben Ishai P, Talary M S, Caduff A, Levy E, Feldman Yu. Electrode polarization in dielectric measurements: a review. Meas. Sci. Technol. 24 (2013) 102001 (21pp).

Livshits L, Caduff A, Talary M, Lutz HU, Hayashi Y, Puzenko A, Shendrik A, Feldman Y. The role of GLUT1 in the sugar induced dielectric response of human erythrocyte membranes. J. Phys. Chem. B, 2009, 113 (7), pp 2212–2220.

Dewarrat F, Falco L, Caduff A, Talary M, Feldman Y, Puzenko A. Measurement and simulation of conductive dielectric two-layer materials with a multiple electrodes sensor. IEEE Transactions on Dielectrics and Electrical Insulation. 2008. October 2008, 15(5): 1406-1414.

Dewarrat F, Falco L, Caduff A, Talary M, Feldman Y, Puzenko A. Measurement and simulation of conductive dielectric two-layer materials with a multiple electrodes sensor. IEEE Transactions on Dielectrics and Electrical Insulation. 2008. October 2008, 15(5): 1406-1414.

Talary, M.S.. Dewarrat, F., Caduff, A., Puzenko, A., Ryabov, Y., Feldman, Y, 2006, An RCL sensor for measuring dielectrically lossy materials in the MHz frequency range. Part I. Comparison of hydrogel model simulation with actual hydrogel impedance measurements, IEEE trans diel elect Insul, 13, No 2, pp. 247- 256.

Electrokinetics/ Micromachining/Microfluidics

Pethig, R, Lee, R.S, and Talary, M.S., 2004, Cell Physiometry tools based on Dielectrophoresis, JALA. 9 No. 5, 324-330.

Pethig, R, Talary, M.S., Lee, R.S., 2004, Enhanced traveling wave dielectrophoresis with signal superposition, IEEE. Eng. Med. Biol. 22 No. 6, 43-50.

Pethig, R., Bressler, V., Carswell-Crumpton, C., Chen, Y., Foster, L.C., Garcia-Ojeda, M.E., Lee, R.S., Lock, G.M., Talary, M.S., Tate, K.M., 2002, Dielectrophoretic studies of the activation of human T lymphocytes using a newly developed cell profiling system, , Journal of Electrostatics, 23, 2057-2063.

Talary, M.S., Burt, J.P.H. & Pethig, R., 1999, Future trends in diagnosis using laboratory-on-a-chip technologies, Parasitology. S117 pp.191-203

Rizvi, N.H., Rumbsby, P.T., Gower, M.C., Burt, J.P.H., Talary, M.S. Tame, J.A. and Pethig, R., 1999, Direct manufacture of Miniature Bio-Particle Electro-Manipulator Devices using Excimer laser Mask Projection Techniques, Int. J. Japan Soc. Prec. Eng. 33 No 2, 100-104.

Pethig, R., Burt, J P H, Parton, A., Rizvi, N., Talary, M S., and Tame, J A. 1998 Development of Biofactory-on-a-Chip Technology using Excimer Laser Micromachining. J. Micromech. Microeng. 8, 57-63

Burt, J. P. H., Pethig, R., and Talary, M. S. 1998. Microelectrode Devices for Manipulating and Analysing Bioparticles, Trans. Inst. Meas. Control. 20: 2, 82-90 Burt, J. P. H., Pethig, R., and Talary, M. S. 1997. Microelectrode Devices for Manipulating and Analysing Bioparticles, Trans. Inst. Meas. Control.

Rizvi, N.H., Harvey, E.C., Rumsby, P.T., Burt, J.P.H., Talary, M.S., Tame, J.A. and Pethig, R.  1997. Direct manufacture of miniature bioparticle electro-manipulators by excimer mask projection.  Proc. Int. Conf. Precision Eng., Taipai, Taiwan 2: 971-974.

Rizvi, N.H., Harvey, E.C., Rumsby, P.T., Burt, J.P.H., Talary, M.S., Tame, J.A. and Pethig, R. 1997. An excimer laser micromachining system for the production of bioparticle electromanipulation devices.  Proc. Int. Soc. Opt. Eng. 3224: 255-272.

Talary, M.S., Burt, J.P.H., Tame, J.A., and Pethig, R. 1996. Electro Manipulation and Separation of Cells using Travelling electric Fields. J. Phys.D.: Appl. Phys. 29: 2198-2203.

Stephens M, Talary M.S., Pethig R, Burnett, A.K. and Mills, K.l. 1996. The dielectrophoresis enrichment of CD34(+) cells from peripheral blood stem cell harvests, Bone Marrow Transpl 18: (4) 777-782.

Burt, J.P.H., Pethig, R., Talary, M.S., and Tame, J.A. 1995. Travelling-Field Electro-Manipulation of Bioparticles, In: International Progress in Precision Engineering (M Bonis, Y Alayli, P Revel, P A McKeown and J Corbett, Eds.) Elsevier, pp. 476-479.

Talary, M.S., Mills, K.I., Hoy, T., Burnett, A.K. and Pethig, R. 1995. Dielectrophoretic separation and enrichment of CD34+ cell subpopulation from bone marrow and peripheral blood stem cells. Med. Biol. Eng. Comp. 33 235-237.

Markx, G.H., Talary, M., and Pethig, R. 1994. Separation of viable and non-viable yeast using dielectrophoresis. J.Biotechnology 32 29-37.

Talary, M.S., and Pethig, R. 1994. Optical technique for measuring the positive and negative dielectrophoretic behaviour of cells and colloidal suspensions. IEEE Proc. Sci. Meas. Technol. 141 395-399.

Quantitative Phase Microscopy

Boss D, Kühn J, Jourdain P, Depeursinge C, Magistretti P.J, and Marquet P. 2013. Measurement of absolute cell volume, osmotic membrane water permeability, and refractive index of transmembrane water and solute flux by digital holographic microscopy. J Biomed Opt 18, 036007-036007.

Boss D, Hoffmann A, Rappaz B, Depeursinge C, Magistretti PJ, Van de Ville D, Marquet P. 2012. Spatially-Resolved Eigenmode Decomposition of Red Blood Cells Membrane Fluctuations Questions the Role of ATP in Flickering. PLoSONE 7(8):e40667.

Cotte Y, Toy F, Jourdain P, Pavillon N, Boss D, et al. 2013. Marker-free phase nanoscopy. Nat Photon 7: 113-117

Yi F, Moon I, Javidi B, Boss D, Marquet P. 2013. Automated segmentation ofmultiple red blood cells with digital holographic microscopy. J Biomed Opt18: 26006.

Jourdain P, Boss D, Rappaz B, Moratal C, Hernandez MC, et al. 2012 Simultaneous optical recording in multiple cells by digital holographic microscopy of chloride current associated to activation of the ligand-gated chloride channel GABA(A) receptor. PLoS ONE 7: e51041.

Moon I, Javidi B, Yi F, Boss D, Marquet P. 2012 Automated statistical quantification of three-dimensional morphology and mean corpuscular hemoglobin of multiple red blood cells. Opt Express 20: 10295-10309.

Jourdain P, Pavillon N, Moratal C, Boss D, Rappaz B, et al. 2011. Determination of Transmembrane Water Fluxes in Neurons Elicited by Glutamate Ionotropic Receptors and by the Cotransporters KCC2 and NKCC1: A Digital Holographic Microscopy Study. The Journal of Neuroscience 31: 11846-11854.

Cotte Y, Toy FM, Arfire C, Kou SS, Boss D, et al. 2011. Realistic 3D coherent transfer function inverse filtering of complex fields. Biomed Opt Express 2: 2216-2230.

Pavillon N, Benke A, Boss D, Moratal C, Kühn J, et al. 2010. Cell morphology and intracellular ionic homeostasis explored with a multimodal approach combining epifluorescence and digital holographic microscopy. Journal of Biophotonics 3:432-436.

Rappaz B, Barbul A, Hoffmann A, Boss D, Korenstein R, et al. 2009. Spatial analysis of erythrocyte membrane fluctuations by digital holographic microscopy. Blood Cells Molecules and Diseases 42: 228-232.